The 36000 BTU Under/Floor Ceiling Split from Green Air-Conditioning is best suited for home, office and industrial use. This aircon will work optimal in rooms and areas with a floor size of up to 60m². Our franchises, agents and dealers are all highly trained professionals and will also be able to assist you with the installation.
Feel free to request a quote or contact us for expert advise.
| Type of Unit | UNDER/FLOOR CEILING | ||
|---|---|---|---|
| Model | UFCM-H36 | ||
| Indoor Power Supply | V~,Hz,Ph | 220~240/50/1 | |
| Cooling | Capacity | Btu/h | 36160 |
| kW | 10.60 | ||
| Input | kW | 3.57 | |
| Rated current | A | 16.30 | |
| EER | W/W | 2.97 | |
| Heating | Capacity | Btu/h | 39920 |
| Kw | 11.70 | ||
| Input | kW | 3.50 | |
| Rated current | A | 15.80 | |
| COP | w/w | 3.34 | |
| Indoor Fan Motor | Model |
FP100F |
|
| Output Power x Fan Quantity | W | 100 x 1 | |
| Capacitor | uF | 5.0 | |
| Speed (Hi/Med/Low) | r/min | 1280/1100/935 | |
| Indoor Coil | Number of Rows | 3 | |
| Tube Pitch (a) x Row Pitch (b) | mm | 20.5 x 12.7 | |
| Fin Pitch | mm | 1.5 | |
| Fin Type | Hydrophilic | ||
| Tube Outside Dia. and Type | mm | 7 Inner grooved | |
| Coil length x height x width | mm | 971 x 307 x 38.1 | |
| Number of Circuits | 5 | ||
| Indoor Airflow (Hi/Mi/Lo) | m³/h | 1600/1260/800 | |
| Indoor noise level (Hi/Mi/Lo) | dB(A) | 50/46/42 | |
| Indoor Unit | Dimension (W x D x H) | mm | 1280 x 235 x 690 |
| Packaging (W x D x H) | mm | 1360 x 325 x 770 | |
| Net/Gross weight | Kg | 36/42 | |
| Wired Controller | YKR-T/021E | ||
| Outdoor Power Supply | V~,Hz,Ph | 220~240/50/1 | |
| Max Input Consumption | W | 5300 | |
| Compressor | Model | ATH420MV-C9EU | |
| Type | Twin Rotary | ||
| Brand | Highly | ||
| Capacity | W | 10060 | |
| Input | W | 3470 | |
| Rated current (RLA) | A | 16.6 | |
| Locked rotor (LRA) | A | 80 | |
| Thermal protector Temp. | 165 | ||
| Capacitor | uF | 45*2 | |
| Refrigerant Oil | ml | 840 | |
| Outdoor Motor Fan | Model | YDK85-6E | |
| Output Power x Fan Quantity | W | 85 x 1 | |
| Capacitor | uF | 4 | |
| Speed | r/min | 855 | |
| Outdoor Coil | Number of rows | 2 | |
| Tube Pitch (a) x Row Pitch (b) | mm | 22 x 19.05 | |
| Fin spacing | mm | 1.5 | |
| Fin type | Hydrophilic aluminum | ||
| Tube outside dia. and type | mm | 7 Inner grooved | |
| Coil length x height x width | mm | 983 x 748 x 38.1 | |
| Number of circuits | 6 | ||
| Outdoor Airflow Volume | m³h / CFM | 3850 / 2265 | |
| Outdoor noise level | dB(A) | 60 | |
| Outdoor Unit | Dimension (W x D x H) | mm | 970 x 395 x 805 |
| Packaging (W x D x H) | mm | 1105 x 495 x 895 | |
| Net/Gross weight | Kg | 65/75 | |
| Refrigerant | Type/Quantity | g | R410a/2200 |
| Design Pressure | MPa | 4.4/1.4 | |
| Connecting Wiring | Power Wiring (Indoor) | mm² | / |
| Power wiring (Outdoor) | mm² | 3 x 4 | |
| Signal wiring | mm² | 3 × 1 + 3 x 1 | |
| Refrigerant Piping | Liquid Side / Gas Side | mm | 9.52/15.88 (3/8 x 5/8) |
| Max Pipe Length | m | 30 | |
| Max High Drop | m | 20 | |
| Ambient Temp | Cooling | °C | -5~49 |
| Heating | °C | -15~24 | |